INDUSTRY
Energy.
DURATION
Works were carried out from 17 August to 10 September 2021 for the rear boxes and from 27 September to 8 October for the front boxes.
EQUIPMENT
TL31 condenser.
MATERIAL
Aluminium brass (Al brass).
PROBLEM
The condenser presented high-level corrosion on the rear water boxes and required a complete reconditioning of the existing coating.
SOLUTION
The anti-corrosion protection procedure involved cleaning, sandblasting and applying a new coating to the condenser’s tube plates and water boxes. Phencote 2000TS and Phencote HR60 resins were used. Thickness checks and dielectric tests were performed to ensure the quality of the coating. The coating was qualified according to the technical and economic requirements of the offer. The report was compiled by a Project Manager Engineer, NACE Level 2 certified Coating Inspector INAC Level B coating inspector.
SERVICE
TL31 condenser corrosion treatment →
Storage tank shell and bottom repair →