INDUSTRY
Nuclear.
EQUIPMENT
CET3 Group 3 condenser.
MATERIAL
Pipes in CU-NI 90/10 and CU-NI 70/30.
PROBLEM
Deterioration of pipes and plates due to corrosive and abrasive phenomena.
SOLUTION
Application of Phencote HR-60 TL resin coating, which offers protection against erosive, corrosive and abrasive phenomena caused by the coolant.
The coating application process involves sandblasting the surfaces, applying a layer of Phencote HR-60 primer and a thick layer Phencote 2000 resin. Intermediate checks were carried out while the coating was being applied to check on its thickness and the absence of discontinuities or imperfections.
The coating exceeded the required technical specifications, presenting a final thickness of approximately 200 microns.
SERVICE
TL31 condenser corrosion treatment →
Storage tank shell and bottom repair →